Pump Switches

VerticalMaster II Pump Switch

Cable:Flexible 18 gauge, 2 conductor (UL, CSA) SJOW
Mounting Bracket & Hose Clamp:Stainless steel
Lift Rod:Injection molded acetal plastic
Float Stop:Neoprene
Switch and Float Housing:High impact, corrosion resistant, PVC housing for use in non-potable water up to 52°C (125°F)
Features
  • Mechanically-activated
  • Designed to operate in sump applications with limited space
  • Adjustable pumping range of 2 to 17 cm
  • Not sensitive to turbulence
  • UL Recognised for use in non-potable water
  • CSA Certified
  • Pump down application only
Datasheet

Dimensions

Overall:30.5 cm high x 12.7 cm x 7.6 cm wide (12" high x 5" x 3" wide)
Switch Housing (not cable entrance):5 cm high x 7.1 cm wide (2" high x 2.8" wide)
Float Housing:6.4 cm high x 6.9 cm wide (2.5" high x 2.7" wide)

Electrical

125/250 VAC 50/60 Hz Single Phase: Maximum Pump Running Current: 10 amps
Maximum Pump Starting Current: 60 amps

NB: This switch must be used with pumps that provide integral thermal overload protection.

NB: This switch is NOT recommended for non-arcing electrical loads

TypeCable LengthPump DirectionPlug *RBS Product No
VerticalMaster II3mPump Downx3710190
VerticalMaster II3mPump Down3710191
VerticalMaster II5mPump Downx3710195
VerticalMaster II5mPump Down3710196
VerticalMaster II10mPump Downx3710200

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

MicroMaster

Cable:Flexible 16 (250VAC) or 18 (125VAC) gauge, 2 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Float Housing:High impact, corrosion resistant, polypropylene housing for use in water up to 60°C (140°F)
Features
  • Mechanically-activated, snap action contacts
  • Designed for performance and dependability
  • Adjustable pumping range of 20 to 91cm (8 to 36")
  • UL Recognised for use in water and sewage
  • CSA Certified
Datasheets

MicroMaster

Microaster AC/DC

Microaster Plus WS

Electrical

125/250 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 10 amps
Maximum Pump Starting Current: 60 amps

NB: This switch must be used with pumps that provide integral thermal overload protection.

NB: This switch is NOT recommended for controlling electric loads less than 100 milliamps (12 VAC), or non-arcing electric loads

TypeCable LengthPump DirectionPlug *RBS Product No
Micromaster3mPump Upx3710350
Micromaster3mPump Downx3710365
Micromaster5mPump Upx3710355
Micromaster5mPump Downx3710370
Micromaster5mPump Down3710371
Micromaster10mPump Upx3710360
Micromaster10mPump Downx3710375
Micromaster10mPump Down3710376
Micromaster20mPump Downx3710380
Micromaster20mPump Down3710381
Micromaster50mPump Downx3710383

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

MicroMaster SPDT

Cable:Flexible 18 gauge, 3 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Float Housing:High impact, corrosion resistant, polypropylene housing for use in water up to 60°C (140°F)
Features
  • Mechanically-activated, snap action contacts
  • Designed for performance and dependability
  • Single Pole, Double Throw
  • Adjustable pumping range of 20 to 91cm (8 to 36")
  • UL Recognised for use in water and sewage
  • CSA Certified
Datasheet

Electrical

125/250 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 10 amps
Maximum Pump Starting Current: 60 amps

NB: This switch must be used with pumps that provide integral thermal overload protection.

NB: This switch is NOT recommended for controlling electric loads less than 100 milliamps (12 VAC), or non-arcing electric loads

TypeCable LengthPump DirectionPlug *RBS Product No
Micromaster SPDT3mPump Up/DownxNA
Micromaster SPDT5mPump Up/Downx3710385
Micromaster SPDT10mPump Up/Downx3710390
Micromaster SPDT20mPump Up/Downx3710391
Micromaster SPDT30mPump Up/Downx3710392
Micromaster SPDT50mPump Up/Downx3710393

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

PumpMaster

Cable:Flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Float Housing:High impact, corrosion resistant, PVC housing for use in sewage and water up to 60°C (140°F)
Features
  • Heavy-duty contacts
  • Designed for direct control of pumps up to 1/2 HP at 120 VAC and 1HP at 230 VAC
  • Includes standard mounting clamp and boxed packaging
  • Adjustable pumping range of 18 to 91cm (7 to 36")
  • UL Recognised for use in non-potable water and sewage
  • CSA Certified
Datasheet

PumpMaster

PumpMaster WPS

Electrical

120/230 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 13 amps
Maximum Pump Starting Current: 85 amps

NB: This switch must be used with pumps that provide integral thermal overload protection.

TypeCable LengthPump DirectionPlug *RBS Product No
PumpMaster3mPump Upx3710020
PumpMaster3mPump Downx3710120
PumpMaster3mPump Down3710121
PumpMaster5mPump Upx3710025
PumpMaster5mPump Up3710026
PumpMaster5mPump Downx3710125
PumpMaster5mPump Down3710126
PumpMaster10mPump Upx3710030
PumpMaster10mPump Up3710031
PumpMaster10mPump Downx3710130
PumpMaster10mPump Down3710131

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

PumpMaster Plus

Cable:Flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Float Housing:High impact, corrosion resistant, PVC housing for use in sewage and water up to 60°C (140°F)
Features
  • Heavy-duty contacts
  • Designed for direct control of pumps up to 3/4 HP at 120 VAC and 2 HP at 230 VAC
  • Includes standard mounting clamp and boxed packaging
  • Adjustable pumping range of 18 to 91cm (7 to 36")
  • UL Recognised for use in water and sewage
  • CSA Certified
Datasheet Datasheet

Electrical

120/230 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 15 amps
Maximum Pump Starting Current: 85 amps

NB: This switch must be used with pumps that provide integral thermal overload protection.

TypeCable LengthPump DirectionPlug *RBS Product No
PumpMaster Plus3mPump UpxNA
PumpMaster Plus3mPump DownxNA
PumpMaster Plus5mPump UpxNA
PumpMaster Plus5mPump DownxNA
PumpMaster Plus10mPump Upx3710070
PumpMaster Plus10mPump Downx3710170

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

PumpMaster SPDT

Cable:Flexible 16 gauge, 3 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Float Housing:High impact, corrosion resistant, PVC housing for use in sewage and water up to 60°C (140°F)
Features
  • Heavy-duty contacts
  • Designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC
  • Single Pole, Double Throw
  • Includes standard mounting clamp and boxed packaging
  • Adjustable pumping range of 18 to 91cm (7 to 36")
  • UL Recognised for use in water and sewage
  • CSA Certified
Datasheets Datasheet

Electrical

120/230 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 13 amps
Maximum Pump Starting Current: 85 amps

NB: This switch must be used with pumps that provide integral thermal overload protection.

TypeCable LengthPump DirectionTetherRBS Product No
PumpMaster Plus3mPump Up/DownPipe Clamp3710460
PumpMaster Plus5mPump Up/DownPipe Clamp3710465
PumpMaster Plus10mPump Up/DownPipe Clamp3710475

AmpMaster Pump Switch

Cable:Flexible 12 gauge, 2 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Float Housing:High impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 50°C (120°F)
Features
  • Heavy-duty contacts mounted on high-conductivity copper substrates
  • Designed for direct control of pumps up to 1 1/2 HP at 125 VAC and 3 HP at 250 VAC
  • Second set of non-conductive contacts enhance switch activation
  • Includes standard mounting clamp and boxed packaging
  • Adjustable pumping range of 23 to 61cm (9 to 24")
  • UL Recognised for use in non-potable water and sewage
  • CSA Certified
  • Pump down application only
Datasheet

Electrical

125/250 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 20 amps
Maximum Pump Starting Current: 120 amps

NB: This switch must be used with pumps that provide integral thermal overload protection. Certain pump applications may require the use of external capacitor start kit.

TypeCable LengthPump DirectionPlug *RBS Product No
AmpMaster3mPump DownxNA
AmpMaster5mPump DownxNA
AmpMaster10mPump Downx3709110

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

Junior Super Single Pump Switch

Cable:Flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Float Housing:High impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 60°C (140°F)
Features
  • Designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC
  • Includes standard mounting clamp and boxed packaging
  • Adjustable pumping range of 16.5 to 48cm (6.5 to 48")
  • UL Recognised for use in non-potable water and sewage
  • CSA Certified
Datasheet

Junior Super Single

Super Single

Electrical

120 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 13 amps
Maximum Pump Starting Current: 40 amps
230 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 8 amps
Maximum Pump Starting Current: 20 amps
TypeCable LengthPump DirectionPlug *RBS Product No
Junior Super Single3mPump UpxNA
Junior Super Single3mPump DownxNA
Junior Super Single5mPump Upx3708926
Junior Super Single5mPump Downx3709026
Junior Super Single10mPump Upx3708928
Junior Super Single10mPump Downx3709028
Junior Super Single15mPump Downx3709030
Junior Super Single20mPump Downx3709032

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

Double Float Pump Switch

Cable (attached to float housing):Flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Cable (above splice):Flexible 14 gauge, 3 conductor (UL, CSA) SJTW, water-resistant, thermoplastic
Float Housing:High impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 60°C (140°F)
Mercury Switch:Mercury-to-mercury contacts, hermetically sealed in a steel capsule
Features
  • Designed for direct control of pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC
  • Includes standard mounting clamps and boxed packaging
  • Adjustable pumping range of 4.45 to 122cm (1.75 to 48") with increased pumping range of up to 1.8m (6 feet) available
  • UL Recognised for use in non-potable water and sewage
  • CSA Certified
Datasheet

Double Float

Double Float Master

Electrical

120 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 15 amps
Maximum Pump Starting Current: 55 amps
230 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 12 amps
Maximum Pump Starting Current: 35 amps

NB: This switch must be used with pumps that provide integral thermal overload protection.

TypeCable LengthPump DirectionPlug *RBS Product No
Double Float5mPump UpxNA
Double Float5mPump DownxNA
Double Float10mPump Upx3710555
Double Float10mPump Downx3710565

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

Quest Pump Switch

Cable:H07 RN 1mm2 2 or 3 conductor (H05 VV also available)
Float Housing:Non-toxic, corrosion resistant, polypropylene housing for use up to 55°C (131°F)
Features
  • Designed for performance and dependability
  • Includes an innovative one-piece cable weight for mounting
  • Adjustable pumping range of 23 to 91cm (9 to 36") with increased pumping range of up to 1.8m (6 feet) available
  • CE Certified
Datasheet Datasheet

Electrical

250 VAC 50/60 Hz10 (8) amp
Micro disconnect
Function Class I and II

NB: This switch must be used with pumps that provide integral thermal overload protection.

NB: This switch is NOT recommended for controlling electric loads less than 100 milliamps (12 VAC), or non-arcing electric loads

TypeCable LengthPump DirectionPlug *RBS Product No
Quest3mPump Upx3710804
Quest5mPump Upx3710806
Quest10mPump Upx3710808
Quest20mPump Upx3710812

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

Quest Pump Switch & Quest SPDT Pump Switch

Cable:H07 RN 1mm2 2 or 3 conductor (H05 VV also available)
Float Housing:Non-toxic, corrosion resistant, polypropylene housing for use up to 55°C (131°F)
Features
  • Designed for performance and dependability
  • Includes an innovative one-piece cable weight for mounting
  • 2-wire (Quest) / 3-wire (Quest SPDT) with weight included
  • Adjustable pumping range of 23 to 91cm (9 to 36") with increased pumping range of up to 1.8m (6 feet) available
  • CE Certified
Datasheet

Electrical

250 VAC 50/60 Hz10 (8) amp
Micro disconnect
Function Class I and II

NB: This switch must be used with pumps that provide integral thermal overload protection.

NB: This switch is NOT recommended for controlling electric loads less than 100 milliamps (12 VAC), or non-arcing electric loads

TypeCable LengthPump DirectionPlug *RBS Product No
Quest3mPump Upx3710804
Quest5mPump Upx3710806
Quest10mPump Upx3710808
Quest20mPump Upx3710812
Quest SPDT3mPump Upx3710824
Quest SPDT5mPump Upx3710826
Quest SPDT10mPump Upx3710828
Quest SPDT20mPump Upx3710830

HiTempMaster Pump Switch

Cable:Flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant, (CPE)
Float Housing:High impact, corrosion resistant, polypropylene housing for use in water up to 93°C (200°F)
Features
  • Designed for performance and dependability in high temperature sump applications
  • Mechanically-activated, snap action contacts
  • Adjustable pumping range of 20 to 91cm (8 to 36")
  • Twin wall design of float housing protects internal components from heat and moisture
  • CSA Certified
  • For pump down applications only
Datasheet

Electrical

125/250 VAC 50/60 Hz Single Phase:Maximum Pump Running Current: 13 amps
Maximum Pump Starting Current: 78 amps

NB: This switch must be used with pumps that provide integral thermal overload protection.

TypeCable LengthPump DirectionPlug *RBS Product No
HiTempMaster3mPump Downx3710000
HiTempMaster6mPump Downx3710010
HiTempMaster10mPump Downx3710014

* Fitted with piggyback plug. Allows you to plug in the pump directly, no further wiring required

NB: This switch is NOT recommended for controlling electric loads less than 100 milliamps (12 VAC), or non-arcing electric loads